FTW-1600T Series - Kiel Planck
  • Home
        • New Product

          FTW-1600T Series - Kiel Planck

          Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

          Need Help?

          Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

          Phone: +1 (xxx) xxx-xxxx
          E-mail: xxx@xxxx.com

  • Application
  • Service
  • Brand
  • Contact Us

FTW-1600T Series

FTW-1600T Series - Kiel Planck

FTW-1600T Series

Insertion Thermal Mass Flow Meter

FTW-1600T Insertion Thermal Gas Mass Flow Meter adoptsThe flow meter designed for the principle of thermal diffusion, speciallyThe door is used to measure dry pipeline gas under extremely complex conditions. It is not afraid of gas chemical properties. It has the characteristics of high measurement accuracy, wide measurement range, large diameter can be measured, and easy installation. Parts, the impact of vibration can be ignored, and the product is displayed with a display, which is convenient for observation.

Specification

Performance Features

FTW-1600T Insertion Thermal Mass Flow Meterbased onhot The flow meter is designed based on the principle of diffusion. That is, when the fluid flows through the heating object, the amount of heat lost by the heating object is proportional to the flow rate of the fluid. The sensors of this series of flowmeters have two standard RTDs, one with It is used as a heat source, and one is used to measure the temperature of the fluid. When the fluid flows, the temperature difference between the two has a linear relationship with the flow rate, and then through the microelectronic control technology, this relationship is converted into the linearity of the measured flow signal. output.

■ Corrosion resistant all stainless steel, ABS Simple structure of full mold production probe

■ Easy installation, simple maintenance, two-way detection, anti-vibration

■ Simultaneous detection of flow and temperature, switching display

■ Large diameter and small flow measurement, can be used for leak detection

■ Direct mass flow detection without temperature and pressure compensation

■ Using SMD devices and surface mount (SMT) technology, high circuit reliability ;

■  The range can be modified online according to the actual needs of users on site to better match the acquisition terminal match;

■ Using RS-485 communication, or HART communication, can realize factory automation and integration

■ With self-diagnosis and self-diagnosis and alarm functions;

■ Low EMI switching power supply, suitable for a wide range of power supply voltage changes, good anti-EMI performance .

Technical parameters
measurement range 0.1-120m/S
Available medium all gases compatible with stainless steel
Nominal pipe diameter DN80-6000
precision class 0.5%FS, 1%FS
Reproducibility error  ±0.25% of measurement
turndown 100:1
display Wide-screen LCD display, parameters and variables can be set by buttons on the panel (with password protection)
operating temperature -40-100℃ (standard), -40-350℃ (for enquiry)
Work pressure <2.5MPa
Shell Material stainless steel, cast aluminum alloy
sensor material 316L, Tantalum, Hastelloy, Titanium
Liquid texture Cover 316G stainless steel (standard), Hastelloy
two-way measurement  yes
Signal Out  4~20mA, RS485, MODBUS protocol, HART output< /span>
response time  ≤850ms
Power supply  24V DC current≥350mA
Electrical connections  M20*1.5 terminal wiring
Connection Flange, ferrule, ferrule+ball valve
Protection level  IP65 (optional IP68)
Ambient temperature  -35~+70℃ Humidity<90%RH< /span>
Relative Humidity  5%~95%
Total power consumption  less than 15W

Related Products Recommendation

MLSS-230 - Kiel Planck

MLSS-230

 Brand DOWESTON Measure range 0~15g/l Resolution 0.01g/l Accuracy ±5%F.S. Operating temperature -20~70℃ Working pressure <0.1MPa Power supply 7~16VDC±10% Signal output Rs485(Modbus/RTU) Liquid connection material Stainless

DD-154 Series - Kiel Planck

DD-154 Series

Mode DD-D154A DD-D154B Range and resolution 0.01~20μS/cm 0.01 0.01~20μS/cm 0.01 0.1~200μS/cm 0.1 0.1~200μS/cm 0.1 0~5000μS/cm 1 0~5000μS/cm 1 0~200mS/cm 0.1 0~200mS/cm 0.1 Accuracy ±1.5%F.S. ±1.5%F.S.

DO-D160 - Kiel Planck

DO-D160

Mode DO-D160 Principle of measurement Fluorescence method Range 0~20mg/L(0~200% saturation,25℃) Resolution 0.01mg/L,0.1℃ Accuracy ±2% of the measured value, or ±0.3mg/L, whichever is greater Temperature compensation

PH-D120 - Kiel Planck

PH-D120

Brand DOWESTON Measure rangge 1~14pH Resolution 0.01pH Accuracy ±0.1pH Operating temperature 0~65℃(0~100℃ optional) Working pressure <0.2MPa Power supply 12~24VDC±10% Signal output Rs485(Modbus/RTU) Liquid connection material

Not sure which Instruments and sensors to choose?

Kilplanck has a number of distributors and a marketing team of more than 100 people covering the global market, providing customers with comprehensive service and support.

Get a product quote

Fill in our quote request form and we will reply to your message as soon as possible! Or send us an email at: xxx@xxx.com

Email
Email: kielplanck@126.com
WhatsApp
WhatsApp Me