Measuring range | 0.01-1000m³/h |
Suitable medium | Clean Liquid (water, aqueous solution, low viscosity oil) |
Nominal pipe diameter | DN4-250MM (flange, clamp) |
DN200-600MM (insert) | |
Accuracy level | ± 0.2% FS、 ± 0.5% FS、 ± 1.0% FS、 ± 1.5% FS |
Repeatability error | ± 0.5% of the measured value |
Linearity | 1% |
Display | Wide-screen LCD display, parameters and variables can be set through the panel keys |
Instantaneous flow display, cumulative total display, percentage display, frequency display | |
L/min、 m3/h、 Hz | |
Resolution | 0.1 l/min、0.005 m3/h |
Operating temperature | -35-60 ° C (standard) |
-20-180 ° C (high temperature type) | |
-40-80 ° C (explosion-proof) | |
Allowed viscosity | 0.8-30cm²/s |
Job stress | 1.6 mpa, 2.5 mpa, 4.0 mpa, special can be customized |
Shell material | Stainless steel, anodic aluminum oxide |
Turbine material | Stainless steel 316L, plastic |
Watch head material | Aluminum alloy |
Bearing | Tungsten carbide bearing, Ruby bearing optional |
Straight pipe section requirements | Entry: 10 * DN |
Export: 5 * DN | |
Signal output | 4-20mA, Pulse, RS485, Modbus protocol, Hart output |
Power supply | 220V AC、24V DC 220V |
Electrical connection | Intelligent: M20 * 1.5 terminal wiring, |
Digital display type: Aviation plug wiring | |
General type: direct line out | |
Connection mode | Standard flange, internal and external threads |
Protection level | IP65(optional IP68) |
Ambient temperature | -20℃…80℃ |
Relative humidity | 5%~95% |
Explosion-proof signs | Explosion-proof ExdIICT4 |
Consume power | <20W |

MLSS-230
Brand DOWESTON Measure range 0~15g/l Resolution 0.01g/l Accuracy ±5%F.S. Operating temperature -20~70℃ Working pressure <0.1MPa Power supply 7~16VDC±10% Signal output Rs485(Modbus/RTU) Liquid connection material Stainless