KP-DIS650

Online digital sensor

KP-DIS650 online PH digital sensor/transmitter 1 ~ 14pH measurement is obtained, digital sensor technology, measurement is no longer erratic. Powerful Modebus RTU/RS-485 transmission mode, rich data bearing, accurate measurement of each data!

Specification

Performance Features

Performance characteristics:

● Signal output: RS-485 (Modbus/RTU protocol).

● Easy to connect to PLC, DCS, industrial control computer, universal controller, paperless recording instrument or touch screen and other third party equipment.

● Double high impedance differential amplifier, strong anti-interference, fast response speed.

● ORP probe, the internal reference fluid exudes very slowly from the microporous salt bridge at a pressure of at least 100 kpa (1Bar), with positive exudation for more than 20 months. This reference system is very stable, and the electrode life is longer than ordinary industrial electrode.

● Easy installation: 3/4NPT pipe thread, easy to sink or mount in pipes and tanks.

● IP68 protection grade.

Technical parameters
Brand KIEL PLANCK
Measure rangge 1~14pH
Resolution 0.01pH
Accuracy ±0.1pH
Operating temperature 0~65℃(0~100℃ optional)
Working pressure <0.2MPa
Power supply 12~24VDC±10%
Signal output Rs485(Modbus/RTU)
Liquid connection material PPR
Installation mode 3/4″ NPT thread
Maintenance It is recommended to clean the electrodes once a month, calibrate them every three months, and replace them once a year.
Screen mode Without
Measurement compensation Temperature compensation NTC2.252K
Dimension 50×45×230mm
Weight 230g
Calibration mode Two-point calibration
Protection class IP68
Principle of measurement Electrochemistry,3mol/L KCL
Power consumption <0.5W

Related Products Recommendation

KP-DSDO750 - Kiel Planck

KP-DSDO750

Mode KP-DSDO750 Principle of measurement Fluorescence method Range 0~20mg/L(0~200% saturation,25℃) Resolution 0.01mg/L,0.1℃ Accuracy ±2% of the measured value, or ±0.3mg/L, whichever is greater Temperature compensation

KP-T200 Series - Kiel Planck

KP-T200 Series

Sensor Thermal resistance, thermocouple Measure range -270-1800℃ Probe length 20-1000mm Probe diameter 3、6(standard)、8mm Output 0-10V、4-20mA,Thermal resistance 、thermocouple Accuracy A class、B class Repetition accuracy ≤0.3%FS/year Error

Not sure which Instruments and sensors to choose?

Kilplanck has a number of distributors and a marketing team of more than 100 people covering the global market, providing customers with comprehensive service and support.

Get a product quote

Fill in our quote request form and we will reply to your message as soon as possible! Or send us an email at: info@kielplanckprc.com / kielplanck@outlook.com

Email
Email: info@kielplanckprc.com
WhatsApp
WhatsApp Me