KP-DK105 Series

Digital corrosion rate sensor

Technical Parameter

Model KP-DK105 KP-DK205 KP-DK305
Measuring range 0..5mm/a 0..5mm/a 0..5mm/a
Principle LRS and EIS LRS and EIS LRS and EIS
Accuracy ±3%FS ±3%FS ±3%FS
Resolution 0.0001 0.0001 0.0001
Temperature range 0..60℃ 0..60℃ 0..60℃
Power supply DC12V, DC24V DC12V, DC24V DC12V, DC24V
Output signal Rs485, 4 – 20mA Rs485, 4 – 20mA Rs485, 4 – 20mA
Calibration method Laboratory comparison method Laboratory comparison method Laboratory comparison method
Shell material PPS ABS stainless steel
Pressure range 0..3bar 0..3bar 0..3bar
Thread G3/4 M39*1.5 G1
Cable length 5m or customize 5m or customize 5m or customize
Probe material Carbon steel, copper, stainless steel Carbon steel, copper, stainless steel Carbon steel, copper, stainless steel
Electrical connection Pin type Pin type Pin type
Protection grade IP68 IP68 IP68

Specification

Performance Features

Technical parameters

Related Products Recommendation

KP-DSDO750 - Kiel Planck

KP-DSDO750

Mode KP-DSDO750 Principle of measurement Fluorescence method Range 0~20mg/L(0~200% saturation,25℃) Resolution 0.01mg/L,0.1℃ Accuracy ±2% of the measured value, or ±0.3mg/L, whichever is greater Temperature compensation

KP-DIS650 - Kiel Planck

KP-DIS650

Brand KIEL PLANCK Measure rangge 1~14pH Resolution 0.01pH Accuracy ±0.1pH Operating temperature 0~65℃(0~100℃ optional) Working pressure <0.2MPa Power supply 12~24VDC±10% Signal output Rs485(Modbus/RTU) Liquid connection

KP-T200 Series - Kiel Planck

KP-T200 Series

Sensor Thermal resistance, thermocouple Measure range -270-1800℃ Probe length 20-1000mm Probe diameter 3、6(standard)、8mm Output 0-10V、4-20mA,Thermal resistance 、thermocouple Accuracy A class、B class Repetition accuracy ≤0.3%FS/year Error