Applicable media | Dry gas, gas, liquid, slightly corrosive liquid, viscous liquid |
Measure range | 1-100pa、6-41000kpa、-1-60MPa |
Range ratio | 1:100 |
Measurement accuracy | ±0.075%FS、±0.1%FS、±0.25%FS、±0.5%FS |
Stability | Up to ±0.10% of the upper range (URL), 60 months |
Pressure type | Gauge pressure, absolute pressure, negative pressure, high static pressure, micro pressure |
Screen | LED field display with three isolation buttons |
Menu adjustment | Adjust by pressing or using Hart communicator |
Input voltage | 12-36V DC |
Output | 4-20mA、RS485、Hart,etc. |
Operating temperature | -35-125℃ |
Overload pressure | 150%FS |
Burst pressure | 300%FS |
Error alarm | Self-diagnostic program detects fault, analog output is higher than 20.8mA or lower than 3.8mA, alarm, high/low flag is adjusted by HART communication |
Ambient temperature | -40-80℃ |
Response time | <1ms (10…90%FS) |
刷新时间 | 0.25S |
service life | >1*10^8 pressure cycles |
Liquid contact material | Stainless Steel 316L (PTFE, PP covered), Hastelloy C, Monel, Tantalum |
shell material | cast aluminum alloy, stainless steel |
Protection class | Electrical part IP67 |
Electrical connections | Terminal wiring, M20*1.5 screw hole*2 |
electrical protection | Overload/Reverse Phase Protection |
Explosion proof | Explosion-proof ExdIICT6, intrinsically safe ExiaIICT4 |
Installation method | G1/2, G1/4, NPT1/2, NPT1/4, M20*1.5 internal and external thread, national standard flange (GB/T 9119- 2010) |
Weight | Approx. 3.0kg |