Intelligent direct-coupled pressure/absolute pressure transmitter
Measuring medium
Measure the pressure of liquids, gases, or vapors
Type of measurement
Gauge pressure measurement, absolute pressure measurement
Output signal
4~20mA digital signal of HART protocol
RS485 serial signal
Measuring range
The compression ratio is recommended for the quantum code range
0B(0~0.6)KPa~6KPa 10:1
0C(0~2)KPa~40KPa 20:1
0E(0~2.5)KPa~250KPa 100:1
0F(0~10)KPa~1MPa 100:1
0G(0~30)KPa~3MPa 100:1
0H(0~0.1)MPa~10MPa 100:1
0I(0~0.21)MPa~21MPa 100:1
0J(0~0.4)MPa~40MPa 100:1
Reference accuracy (including linearity, backfall, repeatability from zero)
±0.05% ±0.075% ±0.1%
If TD>10 (TD = maximum volume/adjustable range), it is:
±(0.005*TD)% ±(0.0075*TD)% ±(0.01*TD)%
Ambient temperature influences
The total influence at (-25~ 65)°C is:
±(0.15*TD 0.05)%*Span
The total influence at (-40~-25)°C and (65~85)°C is:
±(0.2*TD 0.05)%*Span
Overvoltage effects
±0.075%*Span
Long-term stability
±0.1%*Span/3 years
Power Impact
0.001%/10V(12~36)VDC, negligible
Range limit
Within the upper and lower limits of the range, it can be adjusted arbitrarily
It is recommended to choose a volume code with the lowest possible volume ratio to optimize performance characteristics
Zero setting
Scaling range≥ minimum range
Installation location impact
Changes in the mounting position parallel to the diaphragm surface do not cause a zero-point effect.
If the mounting position is not parallel to the diaphragm surface, it can be eliminated by calibration. Countermeasure
There is no impact
Insulation resistance
100MΩ or more to ground (DC500V)
Dielectric strength
Ground AC500V50/60Hz, 1 minute
Response time
The damping constant of the amplifier component is 0.1S, and the sensor time constant is:
(0.1~1.6)S, depending on the range and the ratio of the range. Additional adjustable time
The constant is: (0.1~60)S. For non-linear outputs (e.g. square root function)
The impact depends on the feature and can be calculated accordingly
Ambient temperature: -40~ 85°C-20~ 65°C (with display)
Alarm current
3.6mA offline
21mA upline
The process temperature is -40~125°C
Storage temperature: -40~ 85°C-20~ 65°C (with display)
Electromagnetic compatibility
See Schedule of Electromagnetic Compatibility
Isolation diaphragm
Stainless steel 316L
Hastelloy C-276
tantalum
gild
Process connection materials
Stainless steel 304, 316 optional
Nuts and bolts
Menu
New Product

There is a solution for every application. Let’s work together to find the right solution for you.
Your benefits
We use our experience to move your project forward.
PHONE: 400-8868-261
E-mail: info@kielplanckprc.com / kielplanck@outlook.com