Applicable medium | Can be applied to water, weak acid, weak base, salt solution and other impurities free liquid |
Applicable density | 0.65-2.0g/cm³ |
Measuring range | 300-6000mm |
Accuracy | ±10mm |
Resolution | ±1mm |
Repeatability | ≤±0.2FS/year |
Operating temperature | -20-120℃ (standard type) -20-450 (high temperature type) |
Operating pressure | 0.5-2.5MPa, 1.0-5.0MPa, 2.5-6.0MPa (above 300℃), 2.5-10MPa (below 300℃) |
Output | Switch output, relay output 1-4 switch points optional |
4-20mA,+Hart protocol | |
Overload pressure | 150%FS |
Burst pressure | 200%FS |
Ambient temperature | -40-80℃ |
Liquid contact material | Stainless 304、316L、Ti、PP、PVDF、PTFE、PPR |
Flap indicator | Frame material:SUS304 |
Color material: engineering plastic, ceramic | |
Color: Red/white, green/white | |
Transparent cover material: engineering plastic, glass | |
Protection class | IP65 (Optional IP68) |
Electrical connection | Halsman connector, junction box |
Electrical protection | Overload/reverse protection |
Installation mode | Side installation, bottom in and out, bottom in and out, side in and out, top installation |
Connection mode | Sanitary chuck, flange connection, threaded installation, welded pipe connection |
Attachment | Blowdown valve, heat preservation, heat insulation jacket, dustproof plug head |
Weight | It depends on the range |