Precession vortex flowmeter

Product Overview
The intelligent precession vortex flowmeter is a new type of gas flow meter developed by our company with the leading level in China. The flowmeter integrates the functions of flow, temperature and pressure detection, and can automatically compensate for temperature, pressure and compression factor, which is an ideal instrument for gas metering in petroleum, chemical, electric power, metallurgical and other industries.

Specification

Performance Features

How it works

The flow profile of the flow sensor resembles the profile of a venturi tube. A set of spiral guide vanes are placed on the inlet side, forcing the fluid to create a violent vortex flow as it enters the flow sensor. When the fluid enters the diffusion section, the vortex current is affected by the reflux and begins to rotate twice, forming a gyro-like vortex precession phenomenon. The precession frequency is proportional to the flow rate, and is not affected by the physical properties and density of the fluid, and the precession frequency of the secondary rotation of the fluid measured by the detection element can obtain good linearity in a wide flow range. The signal is amplified, filtered, and shaped by the preamplifier and converted into a pulse signal proportional to the flow rate, and then sent to the microprocessor for accumulation and processing together with the temperature and pressure detection signals, and finally the measurement results (instantaneous flow, cumulative flow, temperature, and pressure data) are displayed on the LCD screen.

Main technical parameters:

DN (mm) Type* Flow range (m³/h) Working pressure (MPa) Accuracy class Repeatability
15 – 1.0 – 10 1.6 – less than 1/3 of the absolute value of the basic error limit
20 – 1.5 – 15
25 – 3.0 – 30
32 – 6.0 – 60
40 – 7.0 – 70 2.5
50 Type A Type B 12 – 150 2.5 – 75 4.0
80 Type A Type B 40 – 400 10 – 200 6.3 10 1.5
100 Type A Type B 80 – 900 30 – 600 16
150 Type A Type B 150 – 1500 40 – 900
200 – 240 – 3600 1.6;2.5;4.0

Note: 1. Accuracy: the system accuracy after temperature and pressure correction;
2. A and B are used to distinguish different flow ranges of the same diameter.

Technical parameters

Related Products Recommendation

KP-DSDO750 - Kiel Planck

KP-DSDO750

Mode KP-DSDO750 Principle of measurement Fluorescence method Range 0~20mg/L(0~200% saturation,25℃) Resolution 0.01mg/L,0.1℃ Accuracy ±2% of the measured value, or ±0.3mg/L, whichever is greater Temperature compensation

KP-DIS650 - Kiel Planck

KP-DIS650

Brand KIEL PLANCK Measure rangge 1~14pH Resolution 0.01pH Accuracy ±0.1pH Operating temperature 0~65℃(0~100℃ optional) Working pressure <0.2MPa Power supply 12~24VDC±10% Signal output Rs485(Modbus/RTU) Liquid connection

Not sure which Instruments and sensors to choose?

Kilplanck has a number of distributors and a marketing team of more than 100 people covering the global market, providing customers with comprehensive service and support.

Get a product quote

Fill in our quote request form and we will reply to your message as soon as possible! Or send us an email at: info@kielplanckprc.com / kielplanck@outlook.com

Email
Email: info@kielplanckprc.com
WhatsApp
WhatsApp Me