Thermal Flow Sensor (Stainless Steel)

Thermal flow switches
Apply:
KIEL PLANCK thermal flow switch adopts precision electronic components widely used in aviation and automobiles, reliable and stable circuit design, so that the flow signal is more accurate and stable, and has been widely used in steel, metallurgy, pharmaceutical, chemical and other industries

Specification

Performance Features

Features:

– LED indicates flow rate
– All stainless steel housing
– No moving parts and no maintenance
– Wide range of sensing probe lengths available
– Easy to install
– One model for multiple pipe diameter requirements
– The switching amount is continuously adjustable
– Virtually no pressure loss
– IP67 protection overall

Product parameters

Project Details
Measuring medium range Water: 3 – 300 cm/s Gas: 200 – 3000 cm/s Oil: 3 – 300 cm/s
Switching accuracy ±1…±10cm/s
Warm-up time: 3 minutes after powering on
Working pressure < 100 Bar
Medium temperature -20°C… 80℃
Process connector G1/2, G1/4 external thread and other threads (customizable)
Output signal PNP/NPN/relay
Power supply 24VDC/85 – 265VA/(50…) 60Hz)
Sensor length 15mm/20mm/30mm/50mm (customizable)
Current consumption: <100mA
Setting: Potentiometer setting
Response time 5(2..15)s
Load current: 250mA, relay: 30VDC/5A, 220VAC/5A
The maximum rate of change of medium temperature is 300K/min
Output protection reverse/overload/short circuit
Degree of protection IP67
Wiring method: M12 connector (cable 1m or customized)
Material ANSI316L

Technical parameters

Related Products Recommendation

KP-DSDO750 - Kiel Planck

KP-DSDO750

Mode KP-DSDO750 Principle of measurement Fluorescence method Range 0~20mg/L(0~200% saturation,25℃) Resolution 0.01mg/L,0.1℃ Accuracy ±2% of the measured value, or ±0.3mg/L, whichever is greater Temperature compensation

KP-DIS650 - Kiel Planck

KP-DIS650

Brand KIEL PLANCK Measure rangge 1~14pH Resolution 0.01pH Accuracy ±0.1pH Operating temperature 0~65℃(0~100℃ optional) Working pressure <0.2MPa Power supply 12~24VDC±10% Signal output Rs485(Modbus/RTU) Liquid connection