Applicable media | Dry gas, poisonous gas, highly corrosive or highly toxic liquid, viscous or easily crystallized liquid |
Measuring range | 1-100pa、6-41000kpa、-1-60MPa |
Turndown ratio | 1:100 |
measurement accuracy | ±0.075%FS, ±0.1%FS, ±0.2%FS, ±0.5%FS |
stability | Up to ±0.10% of upper range limit (URL), 60 months |
pressure type | Gauge pressure, absolute pressure, negative pressure, high static pressure, micro pressure |
show | LED field display with three isolation buttons |
menu adjustment | Adjustment via Hart Communicator |
input voltage | 12-36V DC |
output | 4-20mA, RS485, Hart, etc. |
Operating temperature | -35-125°C |
Overload pressure | 150%FS |
bursting pressure | 300%FS |
error alarm | Self-diagnostic program detects fault, analog output is higher than 20.8mA or lower than 3.8mA, alarm, high/low flag is adjusted by HART communication |
ambient temperature | -40-80℃ |
response time | <1ms (10…90%FS) |
refresh time | 0.25S |
service life | >1*10^8 pressure cycles |
Liquid contact material | Stainless Steel 316L, Hastelloy C, Monel, Tantalum |
shell material | Cast aluminum alloy, stainless steel |
Protection class | Electrical part IP67 |
Electrical connections | Terminal connection, M20*1.5 screw hole *2 |
electrical protection | Overload/Reverse Phase Protection |
Explosion proof | Flameproof ExdIICT6, intrinsic safety ExiaIICT4 |
Damping constant | The electrical damping is 0-32S and can be adjusted at intervals of 0.1S |
Installation method | GB flange (GB/T 9119-2010) |
weight | Approx. 4.4kg |

MLSS-230
Brand DOWESTON Measure range 0~15g/l Resolution 0.01g/l Accuracy ±5%F.S. Operating temperature -20~70℃ Working pressure <0.1MPa Power supply 7~16VDC±10% Signal output Rs485(Modbus/RTU) Liquid connection material Stainless