Product parameters:
Applicable media | Dry gas, gas, liquid, slightly corrosive liquid, viscous liquid |
input voltage | 12-36V DC |
output | 4-20mA, RS485, Hart, etc. |
Operating temperature | -35-125°C |
Overload pressure | 150%FS |
bursting pressure | 300%FS |
error alarm | Self-diagnostic program detects fault, analog output is higher than 20.8mA or lower than 3.8mA, alarm, high/low flag is adjusted by HART communication |
ambient temperature | -40-80℃ |
response time | <1ms (10…90%FS) |
refresh time | 0.25S |
Damping constant | Electrical damping is 0-32S, which can be adjusted at 0.1S intervals |
service life | >1*10^8 pressure cycles |
Liquid contact material | Stainless Steel 316L (PTFE, PP covered), Hastelloy C, Monel, Tantalum |
shell material | cast aluminum alloy, stainless steel |
Protection class | Electrical part IP67 |
Electrical connections | Terminal wiring, M20*1.5 screw hole*2 |
electrical protection | Overload/Reverse Phase Protection |
Explosion proof | Explosion-proof ExdIICT6, intrinsically safe ExiaIICT4 |
Installation method | G1/2, G1/4, NPT1/2, NPT1/4, M20*1.5 internal and external thread, national standard flange (GB/T 9119- 2010) |
weight | Approx. 2.4kg |