Why Oil System Instrumentation Is Important
A compressor may include several independent or interconnected oil systems. The exact configuration depends on the compressor type, driver, lubrication arrangement, hydraulic control design, and project requirements.
A typical installation may include:
Lubricating oil reservoir.
Main oil pump.
Auxiliary or standby oil pump.
Oil cooler.
Oil filter.
Pressure regulating valve.
Distribution manifold.
Bearing oil supply lines.
Control oil or hydraulic power unit.
Oil return lines.
Each component has different monitoring requirements.
If oil pressure is too low, the equipment may not receive the required oil supply. If filter differential pressure increases, the filter may be becoming restricted. If oil temperature rises, the cooling system or operating conditions may require investigation.
However, a measurement signal does not automatically identify the root cause. Pressure, flow, temperature, and level trends should be interpreted together.
1. Lubricating Oil Reservoir: Level and Temperature Monitoring
The lubricating oil reservoir stores oil for circulation through the system.
Two important parameters are oil level and oil temperature.
Oil level
A level instrument can help operators identify insufficient oil inventory or unexpected level changes.
Possible measurement options include:
Point-level switch for high- or low-level alarms.
Continuous level transmitter for ongoing level indication.
Sight glass or local indicator where specified by the equipment design.
The choice depends on tank geometry, oil properties, required alarm functions, and maintenance requirements.
A vibrating fork level switch may be considered for point-level detection if the oil viscosity, temperature, and installation conditions are suitable. For highly viscous oil or oil containing significant deposits, the supplier should confirm whether the selected switch can operate reliably.
Oil temperature
Temperature monitoring helps operators observe the condition of the oil reservoir and the overall lubrication system.
The temperature sensor should be installed at a location that represents the intended measurement. A sensor placed near a heater, return inlet, or stagnant region may not represent the average reservoir condition.
2. Main Oil Pump Outlet: Pressure Monitoring
The main oil pump provides the pressure required to circulate lubricating oil through the system.
A pressure transmitter or pressure switch may be installed at the pump discharge or another designated pressure point.
The measurement can support:
Monitoring of pump discharge pressure.
Detection of abnormal pressure reduction.
Alarm generation.
Verification of pressure-regulating performance.
Trend analysis during startup and normal operation.
The pressure range should be selected according to the pump design and normal operating conditions.
Engineers should distinguish between normal operating pressure, maximum operating pressure, and short-duration pressure peaks. The transmitter’s overload capability must be reviewed separately.
A pressure transmitter should also be selected for compatibility with the oil, process temperature, vibration, electrical output, and required environmental protection.
3. Oil Filter: Differential Pressure Monitoring
The oil filter removes particles from the circulating oil.
As the filter element accumulates contaminants, the pressure difference between the filter inlet and outlet may increase.
Differential pressure monitoring can therefore help operators identify a developing restriction.
A differential pressure transmitter can measure the pressure difference across the filter. In simpler systems, a differential pressure switch may be used to provide an alarm at a defined threshold.
Before selecting the instrument, confirm:
Normal differential pressure across a clean filter.
Expected differential pressure during operation.
Manufacturer’s recommended filter replacement limit.
Maximum pressure on the high and low sides.
Possible pressure transients.
Required alarm or indication function.
The differential pressure alarm setting should follow the filter manufacturer’s guidance and project requirements. It should not be selected using an arbitrary value.
4. Oil Cooler: Inlet and Outlet Temperature, Pressure, and Flow
The oil cooler controls oil temperature by transferring heat to a cooling medium.
Depending on the design, the system may require monitoring of oil temperature at the cooler inlet and outlet, cooling-medium flow, and pressure conditions.
Oil temperature
Temperature measurements before and after the cooler can help operators evaluate the temperature change across the heat exchanger.
Cooling-medium flow
A flow switch may be used to confirm that cooling water or another cooling medium is available. Where continuous flow information is required, a suitable flowmeter may be considered.
Pressure monitoring
Pressure measurements may be required at the cooler inlet and outlet, depending on the project design. These measurements can support troubleshooting and operating-condition monitoring.
The instrument materials and process connections must be compatible with the measured fluid.
5. Oil Distribution Manifold and Bearing Supply Lines
After cooling and filtration, lubricating oil is distributed to bearings and other lubrication points.
Pressure monitoring at the distribution manifold can help verify that the system is supplying oil under the intended conditions.
Some projects may also require individual pressure switches or transmitters for critical branches.
The number and location of measurement points depend on the equipment manufacturer’s design and the consequences of losing oil supply to a particular bearing.
Flow monitoring may be specified for individual branches where the design requires confirmation of minimum flow.
A flow switch provides a point indication, while a flowmeter provides continuous flow information. The required technology depends on the oil viscosity, flow range, pipe size, and installation conditions.
6. Control Oil and Power Oil Systems
Control oil and power oil systems are different from conventional lubrication systems.
They may provide hydraulic pressure to operate control valves, actuators, governing mechanisms, or other equipment.
Important measurement points may include:
Hydraulic pump discharge pressure.
Accumulator pressure.
Pressure at the hydraulic manifold.
Filter differential pressure.
Reservoir level.
Oil temperature.
Return-line pressure, where required.
Accumulator pressure monitoring is particularly important in systems that rely on stored hydraulic energy. The required pressure limits and alarm logic should be based on the accumulator design and equipment manufacturer’s instructions.
A pressure transmitter may be used for continuous monitoring, while a pressure switch may provide a discrete alarm or interlock function.
The pressure instrument must be selected according to the hydraulic system’s operating pressure, transient conditions, fluid compatibility, and safety requirements.
7. Recommended Instrument Measurement Checklist
| Equipment or location | Measurement parameter | Possible instrument |
|---|---|---|
| Oil reservoir | Level | Level switch or level transmitter |
| Oil reservoir | Temperature | Temperature sensor |
| Main oil pump outlet | Pressure | Pressure transmitter or pressure switch |
| Oil filter | Differential pressure | DP transmitter or DP switch |
| Oil cooler inlet/outlet | Temperature | Temperature sensor |
| Cooling-water line | Flow | Flow switch or flowmeter |
| Oil distribution manifold | Pressure | Pressure transmitter |
| Critical lubrication branch | Flow | Flow switch or flowmeter, if required |
| Hydraulic accumulator | Pressure | Pressure transmitter or pressure switch |
| Hydraulic reservoir | Level | Level switch or level transmitter |
This table is a starting point for engineering review, not a universal instrument list. The approved P&ID and equipment manufacturer’s documentation should determine the final measurement points.
8. Common Instrument Selection Mistakes
Using one pressure range for every oil system
Lubrication, control oil, and power oil systems may operate at different pressures. Each measurement point should be evaluated independently.
Ignoring filter differential pressure
Monitoring only the pump outlet pressure may not reveal a developing filter restriction.
Choosing a level switch without checking oil viscosity
Highly viscous or contaminated oil may affect some level detection technologies.
Confusing flow indication with flow protection
A flowmeter provides a measurement, while a flow switch provides a switching signal. The control function should determine which one is needed.
Ignoring vibration and temperature
Instruments installed near pumps and compressors may experience vibration and temperature changes. These conditions should be included in the selection process.
Conclusion
Compressor lubricating oil, control oil, and power oil systems require a coordinated instrumentation arrangement. Pressure monitoring helps verify supply conditions, differential pressure monitoring supports filter maintenance, flow monitoring can confirm circulation, and level monitoring helps protect oil inventory.
The most useful starting point is to review the compressor P&ID and divide the system into reservoirs, pumps, filters, coolers, distribution lines, and hydraulic components. Each point should then be assigned a clear measurement or alarm function.
Selecting pressure transmitters, differential pressure instruments, flowmeters, and level switches according to actual operating conditions can help compressor manufacturers and system integrators build more reliable oil system packages.